PRODUCT

Major Products

UPS k-series

KGP Single Phase/Single Phase
KGPM Three Phase/Single Phase

A pure sine wave, IGBT inverter–based online double-conversion UPS,
delivering uninterrupted, high-quality power to a wide range of IT and industrial equipment.

Features

  • Application servers, storage systems, workstations, and network equipment
  • Pure online double-conversion
  • Pure sine wave output
  • IGBT inverter
  • Transfer time: uninterrupted (0 ms)
  • Automatic battery charging in UPS off mode
  • Overload, online, and battery status indication via LED/LCD
  • Battery hot-swap supported
  • Forced air cooling system
  • Surge, circuit, and overload protection
  • EMI/RFI noise filtering
  • Input/output voltage, frequency, backup time, and temperature display supported
  • SNMP card (optional)

Electrical Specifications

MODEL
MODEL
KGP5
KGP10
KGP15
KGP20
KGPM10
KGPM15
KGPM20
KGPM30
Capacity (VA/Watts)
Capacity (VA/Watts)
5KVA/4KW
10KVA/8KW
15KVA/12KW
20KVA/16KW
10KVA/8KW
15KVA/12KW
20KVA/16KW
30KVA/24KW
Spec
Weight(kg)
63
100
180
200
132
200
236
323
Spec
W×D×H(mm)
230x580x720
305x585x864
409x798x1044
409x798x1044
305x585x864
409x798x1044
555x741x1200
555x741x1200
Input
Nominal Voltage
Single Phase 220V
Single Phase 220V
Single Phase 220V
Single Phase 220V
Three Phase 380V (3Ph+N+PE)
Three Phase 380V (3Ph+N+PE)
Three Phase 380V (3Ph+N+PE)
Three Phase 380V (3Ph+N+PE)
Input
Voltage Range
176V ~ 264V
176V ~ 264V
176V ~ 264V
176V ~ 264V
380V (±20%)
380V (±20%)
380V (±20%)
380V (±20%)
Input
Frequency Range
50 / 60Hz(±5%)
50 / 60Hz(±5%)
50 / 60Hz(±5%)
50 / 60Hz(±5%)
50 / 60Hz(±5%)
50 / 60Hz(±5%)
50 / 60Hz(±5%)
50 / 60Hz(±5%)
Input
Current(A)
34
56
80
104
23
34
45
68
Output
Voltage
Single Phase 220V(±1%)
Single Phase 220V(±1%)
Single Phase 220V(±1%)
Single Phase 220V(±1%)
Single Phase 220V(±1%)
Single Phase 220V(±1%)
Single Phase 220V(±1%)
Single Phase 220V(±1%)
Output
Frequency Range
50 / 60Hz(±5%))
50 / 60Hz(±5%))
50 / 60Hz(±5%))
50 / 60Hz(±5%))
50 / 60Hz(±5%))
50 / 60Hz(±5%))
50 / 60Hz(±5%))
50 / 60Hz(±5%))
Output
AVR Function
Included
Included
Included
Included
Included
Included
Included
Included
Output
THD
≤ 1.5% (Linear Load)
≤ 1.5% (Linear Load)
≤ 1.5% (Linear Load)
≤ 1.5% (Linear Load)
≤ 1.5% (Linear Load)
≤ 1.5% (Linear Load)
≤ 1.5% (Linear Load)
≤ 1.5% (Linear Load)
Output
Crest factor
3:1(Max)
3:1(Max)
3:1(Max)
3:1(Max)
3:1(Max)
3:1(Max)
3:1(Max)
3:1(Max)
Output
Efficiency
85%
90%
90%
90%
90%
90%
90%
90%
System
Transfer Time
0 ms(Line Mode to Battery Mode)
0 ms(Line Mode to Battery Mode)
0 ms(Line Mode to Battery Mode)
0 ms(Line Mode to Battery Mode)
0 ms(Line Mode to Battery Mode)
0 ms(Line Mode to Battery Mode)
0 ms(Line Mode to Battery Mode)
0 ms(Line Mode to Battery Mode)
System
Options
Current limiting, automatic power shutdown, switch protection
Current limiting, automatic power shutdown, switch protection
Current limiting, automatic power shutdown, switch protection
Current limiting, automatic power shutdown, switch protection
Current limiting, automatic power shutdown, switch protection
Current limiting, automatic power shutdown, switch protection
Current limiting, automatic power shutdown, switch protection
Current limiting, automatic power shutdown, switch protection
System
Overload Protection
120% for less than 1 minute
120% for less than 1 minute
120% for less than 1 minute
120% for less than 1 minute
120% for less than 1 minute
120% for less than 1 minute
120% for less than 1 minute
120% for less than 1 minute
Battery
Type
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Optional
Battery
DC Voltage
192 Vdc
192 Vdc
192 Vdc
192 Vdc
192 Vdc
192 Vdc
192 Vdc
240 Vdc
Battery
Backup Time
More than 30 minutes (varies depending on load) – extendable
More than 30 minutes (varies depending on load) – extendable
More than 30 minutes (varies depending on load) – extendable
More than 30 minutes (varies depending on load) – extendable
More than 30 minutes (varies depending on load) – extendable
More than 30 minutes (varies depending on load) – extendable
More than 30 minutes (varies depending on load) – extendable
More than 30 minutes (varies depending on load) – extendable
Battery
Charging Time
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Approx. 8 hours to 90% full charge (varies depending on battery capacity)
Display
LCD Display
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Operating mode, input/output voltage, input/output frequency, battery voltage, temperature, load, etc
Display
LED Indicators
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Battery low voltage, online mode, inverter mode, bypass, abnormal operation
Communication
Communication
RS-232, SNMP card (optional)
RS-232, SNMP card (optional)
RS-232, SNMP card (optional)
RS-232, SNMP card (optional)
RS-232, SNMP card (optional)
RS-232, SNMP card (optional)
RS-232, SNMP card (optional)
RS-232, SNMP card (optional)
Environment
Operating Temperature
0 ~ 40 °C
0 ~ 40 °C
0 ~ 40 °C
0 ~ 40 °C
0 ~ 40 °C
0 ~ 40 °C
0 ~ 40 °C
0 ~ 40 °C
Environment
Storage Temperature
-25 ~ 55 °C
-25 ~ 55 °C
-25 ~ 55 °C
-25 ~ 55 °C
-25 ~ 55 °C
-25 ~ 55 °C
-25 ~ 55 °C
-25 ~ 55 °C
Environment
Humidity
0~95% (Non condensing)
0~95% (Non condensing)
0~95% (Non condensing)
0~95% (Non condensing)
0~95% (Non condensing)
0~95% (Non condensing)
0~95% (Non condensing)
0~95% (Non condensing)
Environment
Altitude
Below 1500 meters
Below 1500 meters
Below 1500 meters
Below 1500 meters
Below 1500 meters
Below 1500 meters
Below 1500 meters
Below 1500 meters
Environment
Noise
≤ 55dB
≤ 55dB
≤ 55dB
≤ 55dB
≤ 55dB
≤ 55dB
≤ 55dB
≤ 55dB

* The enclosure dimensions and weight are based on the rated load capacity and may vary depending on application and operating characteristics.